Product view - REACT V with Belimo - Circular
Product view - REACT V with Belimo - Rectangular
REACT V
Variable flow damper
- Variable or constant flow regulation
- Can be mounted directly at bends and duct transitions/reductions (circular)
- Possible to choose Gruner, Belimo or Siemens actuator
- Possible to choose different communication protocols
- Can be easily anti-condensation insulated in the duct system
- Variants:
- REACT V GMB - Modbus and analogue control (Gruner)
- REACT V-SR GMB - Modbus and analogue control, spring return (Gruner)
- REACT V BMP - Mp-Bus and analogue control (Belimo)
- REACT V BMB - Modbus and analogue control (Belimo)
- REACT V BBAC - BACnet and analogue control (Belimo)
- REACT V SKNX - KNX control (Siemens)
- Circular connections: Ø100-630 mm
- Rectangular connections: 200x200-1400x700 mm
- Intended for flow regulation of comfort ventilation.
- Moist, cold and aggressive environments must be avoided.
- Can be installed in both supply and extract air systems.
- Pressure independent but recommended working range between minimum pressure drop of 10 Pa to 300 Pa over the damper.
- The minimum air flow must be considered during design.
- For good regulation, a minimum difference between Vmin and Vmax of 20% of the product’s Vnom is recommended.
FLOW RANGE | ||||||
REACT V – Gruner Size | Min. | Max.* | ||||
l/s | m3/h | l/s | m3/h | |||
100 | 5 | 18 | 67 | 241 | ||
125 | 9 | 32 | 108 | 389 | ||
160 | 16 | 58 | 184 | 662 | ||
200 | 25 | 90 | 292 | 1051 | ||
250 | 40 | 144 | 470 | 1692 | ||
315 | 63 | 227 | 747 | 2689 | ||
400 | 102 | 367 | 1240 | 4464 | ||
500 | 164 | 590 | 1900 | 6840 | ||
630 | 300 | 1080 | 2950 | 10620 | ||
* Nominal flow (Vnom), based on 120Â Pa in pressure reading. | ||||||
FLOW RANGE | ||||||
REACT V – Belimo Size | Min. | Max.* | ||||
l/s | m3/h | cfm | l/s | m3/h | cfm | |
100 | 5 | 18 | 11 | 58 | 209 | 123 |
125 | 9 | 32 | 19 | 97 | 349 | 206 |
160 | 16 | 58 | 34 | 170 | 612 | 360 |
200 | 25 | 90 | 53 | 272 | 979 | 576 |
250 | 40 | 144 | 85 | 438 | 1577 | 928 |
315 | 63 | 227 | 133 | 710 | 2556 | 1504 |
400 | 102 | 367 | 216 | 1155 | 4158 | 2447 |
500 | 164 | 590 | 347 | 1850 | 6660 | 3920 |
630 | 300 | 1080 | 636 | 2920 | 10512 | 6187 |
* Nominal flow (Vnom), based on 120Â Pa in pressure reading. | ||||||
FLOW RANGE | ||||||
REACT V – Siemens Size | Min. | Max.* | ||||
l/s | m3/h | cfm | l/s | m3/h | cfm | |
100 | 5 | 18 | 11 | 58 | 209 | 123 |
125 | 9 | 32 | 19 | 95 | 342 | 201 |
160 | 16 | 58 | 34 | 170 | 612 | 360 |
200 | 25 | 90 | 53 | 280 | 1008 | 593 |
250 | 40 | 144 | 85 | 445 | 1602 | 943 |
315 | 63 | 227 | 133 | 730 | 2628 | 1547 |
400 | 102 | 367 | 216 | 1190 | 4284 | 2521 |
500 | 164 | 590 | 347 | 1870 | 6732 | 3962 |
* Nominal flow (Vnom), based on 120Â Pa in pressure reading. |
Filtrer
Omfattende og detaljeret produktinformation for bedste udvalg og integration i projektdesign
Installation, drift og vedlighold samt sikkerhedsinformation
Vores produkter og service præsenteret i et let tilgængeligt format
Erklæringer og certifikater mm
Fortrådningsdiagram og hydrauliske skemaer etc.
Dokument | Artikel | Dokumenttype | Dato | Download |
---|---|---|---|---|
Funktionsbeskrivelse & tilslutningsdiagram – Belimo (pdf 1.68MB) | REACT V BMB, REACT V BMP, REACT V BBAC, REACT Parasol Zenith | DV-manual | 17.10.2023 | |
Modbus-indstillinger – Belimo (pdf 146.3kB) | REACT V BMB, REACT Parasol Zenith | DV-manual | 16.10.2023 | |
Brugsanvisning – Belimo Modbus (pdf 2.19MB) | REACT V BMBa | DV-manual | 09.01.2024 | |
Brugsanvisning – Belimo BACnet (pdf 2.18MB) | REACT V BBACa | DV-manual | 09.01.2024 | |
Brugsanvisning – Belimo MP-bus (pdf 2.31MB) | REACT V BMPa | DV-manual | 09.01.2024 | |
Modbus-indstillinger – Gruner (pdf 124.63kB) | REACT ALS, REACT M, REACT P, REACT P-X, REACT V | DV-manual | 05.10.2023 | |
Produktblad – Belimo MP-Bus (pdf 1.38MB) | REACT V BMPa | Teknisk katalog | 05.10.2023 | |
Produktblad – Belimo BACnet (pdf 1.35MB) | REACT V BBACa | Teknisk katalog | 05.10.2023 |